Overview

Data Centre

CX2 Data Centre

Network Infrastructure is the single most important factor in evaluating a hosting service. Webqom continually invests in network equipment, infrastructure and backbone connectivity in all our Data Centres to ensure that our customers' websites get the fastest possible access to their viewers.

Webqom has multiple connections providing connectivity to the following providers / locations with best routing and performance, without 3rd party network involvement. The number of connections is continually increasing.

Physically hosted in CX2 data centre located at Cyberjaya, CX2 data centre carries the following features:

  • Data Center Area: 17,500ft².
  • Floor Load: 10kN per square meter.
  • Floor Height: 3200mm (raised floor to ceiling).
  • Raised Floor: 1000mm.
  • Riser: Two risers for path redundancy.
  • Open Rack Area and Secured Cage Configuration.
  • Passenger Lift: 2 nos. 1.6 ton lifts - 1.5 m width x 2.4m depth x 2.4m height.
  • Insulation: Brick wall with mineral wool and gypsum board insulation.
  • Parking Lots: 135 spaces (32 covered spaces).

Key Features

  • Power Architecture
    • Mains Power: 2 x 33kV incomers from 2 sources.
    • Redundancy: N+1 or N+N option.
    • Distribution: 415V busbar system.
    • Transformers: Up to 24MVA cast resin transformers.
    • Generators: Up to 24MVA diesel generators.
    • Fuel Storage: 30 hours support at full load.
    • Fuel Delivery: 4 hours response.
    • UPS: N+1 or N+N option with minimum 10 minutes backup.
    Cooling System
    • Cooling: Chilled water system and Air Cooled System.
    • Resilience: N+1.
    • Temperature: 18 C to 24 C.
    Telecommunications
    • Carrier Neutral facility with Local MMR Access.
    • MDF: 4 rooms.
    • MMR: 2 rooms.
  • Building Management
    • 24x7 security team, CCTV system, proximity card reader & barrier.
    • Temperature & humidity monitoring & M&E operation & power monitoring.
    • Humidity: 35% to 65% RH.
    Security Management
    • Presence: 24 x 7 security team.
    • Personnel: Proximity card readers, upgradeable to biometric.
    • Vehicle: Barrier control.
    • Delivery: Managed by security personnel.
    • CCTV: Multiple CCTV cameras with offsite archival.
    Fire & Safety System
    • Fire Detection: High sensitivity smoke detectors (HSSD).
    • Fire Suppression: Water mist system in data centre and common area & gas system in mechanical and electrical area.


Gallery

  • Secure Double-Layered Glass Entrance
    Secure Double-Layered Glass Entrance
  • Secure Hallway to DC
    Secure Hallway to DC
  • Racks of Servers and Equipments
    Racks of Servers and Equipments
  • Premier Collocation
    Premier Colocation
  • Rack Space for Collocation
    Rack Space for Collocation
  • Rack Space for Dedicated Servers
    Rack Space for Dedicated Servers
  • Floor Height 3200mm Raised Floor to Ceiling
    Floor Height 3200mm Raised Floor to Ceiling
  • Dual 33kV Power Feed from TNB
    Dual 33kV Power Feed from TNB
  • First Class Facilities
    First Class Facilities
  • Raised Floor 1000mm
    Raised Floor 1000mm
  • Cold Aisle Containment System
    Cold Aisle Containment System
  • Carrier Neutral Facility with Local MMR Access
    Carrier Neutral Facility with Local MMR Access
  • Open Rack Area and Secured Cage Configuration
    Open Rack Area and Secured Cage Configuration